메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Shichang Zhang (Southeast University) Kunting Miao (Nanjing Forestry University) Yang Wei (Nanjing Forestry University) Xiaoming Xu (Arcplus Institute of Shanghai Architectural Design and Research) Bin Luo (Southeast University) Weizhou Shi (Arcplus Institute of Shanghai Architectural Design and Research)
저널정보
한국콘크리트학회 International Journal of Concrete Structures and Materials International Journal of Concrete Structures and Materials Vol.17 No.2
발행연도
2023.3
수록면
269 - 290 (22page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Concrete-filled steel tube (CFST) columns are widely used in civil engineering because of their excellent bearing capacity; however, the reinforcement of CFST columns lacks effective measures. To strengthen CFST columns quickly and effectively, two methods, namely, winding FRP (fiber reinforced polymer) or steel strips, were explored in this work. Two unconfined CFST columns, eight FRP-strengthened CFST columns and four welded steel strip-strengthened CFST columns were manufactured and tested. The failure modes and axial load–strain curves of all specimens under compression load were concluded and compared. The effects of the primary parameters, such as FRP layers (1, 2, 3 and 4 layers) and steel strip thickness (3.0 and 6.0 mm), on the bearing capacity and deformation capacity were also investigated. The ultimate load of CFST columns increased from 28.72 to 64.16% after being confined by FRP with one to four layers. The ultimate load of the welded steel strip-strengthened CFST column with 3.0 mm steel strips and 6.0 mm steel strips increased by 28.46% and 49.82%, respectively, compared with the unconfined CFST column. Thus, the increase in FRP layers and steel strip thickness can markedly improve the compressive behavior of the FRP/welded steel strip-strengthened CFST columns. The cost performance of the two different reinforcement methods also showed that the cost of the welded steel strip-strengthened CFST column is nearly 40% of that of the FRP-strengthened CFST column when the same strengthening effect was obtained, which indicated that the welded steel strip-strengthened CFST column is more cost-efficient than CFST columns confined by FRP. Finally, six existing models for the ultimate load of FRP-strengthened CFST columns were presented and evaluated. From the evaluation results, the Zhang et al.’s model, Lu et al.’s model and Hu et al.’s model for FRP-strengthened CFST columns were shown to provide the best applicability and accuracy. Based on the Mander et al.’s model, a model for the ultimate load of welded steel strip-strengthened CFST columns was proposed and evaluated. The proposed model can accurately predict the ultimate load of welded steel strip-strengthened CFST columns.

목차

Abstract
1 Introduction
2 Experimental Program
3 Results and Discussion
4 Model for Ultimate Load of FRP/Welded Steel Strip‑Strengthened CFST Columns
5 Conclusions
References

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2023-532-000441886